Q1:-Name of 1-phase motors.
Ans:- names of 1-phase motors are giving bellow
- capacitor start induction motor
- permanent capacitor motor
- capacitor start capacitor run motor
- shaded pole motor
- universal motor
Q2:-Why capacitor is installed in 1-phase motor and which winding it have?
Ans:- for increasing the starting toque, and it is put series with starting winding.
Q3:- After starting a 1-phase motor starting winding not disconnected then?
Ans:- Motor's staring winding will be burn with humming noise with in few mint.
Q4:- The range of capacitor used in ceiling fan and table fan
Ans:- 2 to 2.5 microF
Q5:-If fan speed is reversed with slow speed what may be problem with?
Ans:- capacitor burn out
Q6:- where centrifugal switch is put in 1-phase motor why?
Ans:- in series with starting winding it installed . when motor pick up it's speed 70% to 75% then centrifugal switch disconnect the starting winding
Q7:- Staring winding have in 1-phase induction motor?
Ans:- high resistance
Q8:- What is the aim of compensating winding ?
Ans:- compensating winding is used to improve commutation.
Q9:- The difference b/w starting winding and running winding?
Ans:- 90 degree (Electrical)
Q10:- Motors used in
Ans:- some motor's used given below
- Lathe m/c - capacitor start induction motor
- Freez - capacitor start capacitor run motor
- Room Cooler - permanent capacitor motor
- Mixi - universal motor
- Portable hand dril - universal motor
- Hutter syren - universal motor
No comments: