Sunday, June 26, 2016

T10 QUIZ Phase-7 (1-phase I.M.)

Q1:- Applying A.C. to a D.C. shunt motor field causes a high impedance because of the winding's

  1. high resistance
  2. inductive reactance
  3. high induced voltage
  4. capacitive reactance
ANSWER:-2

Q2:- In universal motor armature reaction is reduced by

  1. shifting the brushes
  2. using equalizer connection
  3. connecting a compensating winding in series with the armature.
  4. increasing the number of armature coils
ANSWER:-3

Q3:- An amplidyne is actualy a/an

  1. D.C. amplifier
  2. A.C. amplifier
  3. induction motor
  4. 3-phase generator
ANSWER:-1

Q4:- In normal situation which motor run at 5000 rpm 

  1. synchronous motor
  2. induction motor 
  3. universal motor
  4. none
ANSWER:-3

Q5:- A D.C. series motor does not operate on A.C.becauses

  1. poor efficiency on A.C.
  2. poor power Pf
  3. excessive sparking on A.C.
  4. all
ANSWER:-4

Q6:-Single phase motor are classified on the basis of 

  1. construction
  2. starting method
  3. size
  4. rpm
  5. both construction and starting method.
ANSWER:-5

Q7:- To overcome the effects of poor power pf an A.C. series motor uses

  1. lamination iron in the motor frame
  2. high resistance windings
  3. a brush shifting yoke
  4. more filed turns than a D.C. field
ANSWER:-1

Q8:-The starting torque of capacitor start induction motor is

  1. zero
  2. low
  3. equal to rated torque
  4. more than rated torque
ANSWER:-2

Q9:- If single phase motor fail to start and giving humming noise because

  1. low voltage
  2. high voltage
  3. wrong connection
  4. due to short circuited winding 
ANSWER:-4

Q10:- Which method is cheap and easy to start 1-phase motor 

  1. resistance stat method 
  2. induction start method
  3. capacitance start method
  4. split phase method
ANSWER:-3

No comments:

Post a Comment